Description for Schneider TeSys Vario - emergency stop switch disconnector - 25 A - back of enclosure VCCF0
TeSys Vario switch disconnector for mounting at back of an enclosure, 3 poles, 25A/690V, for motor switching applications up to 7.5kW@400V AC-23. Complete unit composed of a switch body V0, an extension shaft VZ17, a door interlock plate KZ32, a red handle with yellow 60x60mm front plate KCF1PZ. Intended for main and emergency stop switch disconnecting usage. Padlockable handle, for 3 padlocks (to be ordered separately). Handle with 4 screws fixing on door, ensuring IP65 to the mounting. Possible distance between back of enclosure and door 300-330mm. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Features
Main Range TeSys Product Name TeSys VARIO Device Short Name VCCF Product Type Emergency stop switch disconnector
Complementary Device Composition Shaft extension
Switch
Handle Mounting Support Handle: door
Switch: symmetrical rail
Switch: plate Mounting Method By 4 screws for handle
By clips for switch
By screws for switch Performance Level High performance Number of Poles 3P Contact Type and Composition 3 NO [Ue] IEC Rated Operational Voltage 690 V AC 50/60 Hz IEC Rated Operational Power in W 11 kW at 500 V (AC-23A)
11 kW at 690 V (AC-3)
15 kW at 690 V (AC-23A)
4 kW at 230...240 V (AC-3)
5.5 kW at 400...415 V (AC-3)
7.5 kW at 500 V (AC-3)
5.5 kW at 230...240 V (AC-23A)
7.5 kW at 400...415 V (AC-23A) [Ie] Rated Operational Current 14.5 A AC-23 Ue: 400 V [Ith] Conventional Free Air Thermal Current 25 A [Ithe] Conventional Enclosed Thermal Current 20 A Making Capacity ( I Rms) 250 A at 400 V AC-21A
250 A at 400 V AC-22A
250 A at 400 V AC-23A Breaking Capacity 200 A at 400 V (AC-21A)
200 A at 400 V (AC-22A)
200 A at 400 V (AC-23A) Rated Conditional Short Circuit Current 10 kA at 400 V - associated fuse 25 A aM
10 kA at 400 V - associated fuse 25 A gG [Icm] Rated Short Circuit Making Capacity 1 kA at 400 V at Ipeak [Icw] Rated Short Time Withstand Current 300 A at 400 V duration: 1 s [Uimp] Rated Impulse Withstand Voltage 8 kV Suitability for Isolation Yes Network Type AC
DC Intermittent Duty Class 30 Control Type Rotary handle Rotary Handle Mounting Style Extended Handle Color Red Handle Front Plate Color Yellow Rotary Handle Padlocking 1 to 3 padlocks 4…8 mm Marking 0 - 1 Mechanical Durability 100000 cycles Electrical Durability 100000 cycles AC-21
30000 cycles DC-1...5 IEC Terminal Connection Power circuit: screw clamp terminals10 mm² - solid
Power circuit: screw clamp terminals6 mm² - flexible - with cable end Tightening Torque Power circuit: 2.1 N.m - on screw clamp terminals Base Dimension 60 x 60 mm Height 74 mm Width 60 mm Product Weight 0.527 kg
Environment Standards IEC 60947-3 Product Certifications UL
CSA
CCC
GL
UKCA Degree of Protection IP20 conforming to IEC 60529
IP65 Protective Treatment TC Mechanical Robustness Vibrations 10...150 Hz (1 gn) conforming to IEC 60068-2-6
Shocks 11 ms (30 Gn) conforming to IEC 60068-2-27 Ambient Air Temperature for Operation -20…50 °C Fire Resistance 960 °C conforming to IEC 60695-2-1 Compatibility Code Main switch disconnector
Range | TeSys |
---|---|
Product Name | TeSys VARIO |
Device Short Name | VCCF |
Product Type | Emergency stop switch disconnector |
Device Composition | Shaft extension Switch Handle |
---|---|
Mounting Support | Handle: door Switch: symmetrical rail Switch: plate |
Mounting Method | By 4 screws for handle By clips for switch By screws for switch |
Performance Level | High performance |
Number of Poles | 3P |
Contact Type and Composition | 3 NO |
[Ue] IEC Rated Operational Voltage | 690 V AC 50/60 Hz |
IEC Rated Operational Power in W | 11 kW at 500 V (AC-23A) 11 kW at 690 V (AC-3) 15 kW at 690 V (AC-23A) 4 kW at 230...240 V (AC-3) 5.5 kW at 400...415 V (AC-3) 7.5 kW at 500 V (AC-3) 5.5 kW at 230...240 V (AC-23A) 7.5 kW at 400...415 V (AC-23A) |
[Ie] Rated Operational Current | 14.5 A AC-23 Ue: 400 V |
[Ith] Conventional Free Air Thermal Current | 25 A |
[Ithe] Conventional Enclosed Thermal Current | 20 A |
Making Capacity ( I Rms) | 250 A at 400 V AC-21A 250 A at 400 V AC-22A 250 A at 400 V AC-23A |
Breaking Capacity | 200 A at 400 V (AC-21A) 200 A at 400 V (AC-22A) 200 A at 400 V (AC-23A) |
Rated Conditional Short Circuit Current | 10 kA at 400 V - associated fuse 25 A aM 10 kA at 400 V - associated fuse 25 A gG |
[Icm] Rated Short Circuit Making Capacity | 1 kA at 400 V at Ipeak |
[Icw] Rated Short Time Withstand Current | 300 A at 400 V duration: 1 s |
[Uimp] Rated Impulse Withstand Voltage | 8 kV |
Suitability for Isolation | Yes |
Network Type | AC DC |
Intermittent Duty Class | 30 |
Control Type | Rotary handle |
Rotary Handle Mounting Style | Extended |
Handle Color | Red |
Handle Front Plate Color | Yellow |
Rotary Handle Padlocking | 1 to 3 padlocks 4…8 mm |
Marking | 0 - 1 |
Mechanical Durability | 100000 cycles |
Electrical Durability | 100000 cycles AC-21 30000 cycles DC-1...5 |
IEC Terminal Connection | Power circuit: screw clamp terminals10 mm² - solid Power circuit: screw clamp terminals6 mm² - flexible - with cable end |
Tightening Torque | Power circuit: 2.1 N.m - on screw clamp terminals |
Base Dimension | 60 x 60 mm |
Height | 74 mm |
Width | 60 mm |
Product Weight | 0.527 kg |
Standards | IEC 60947-3 |
---|---|
Product Certifications | UL CSA CCC GL UKCA |
Degree of Protection | IP20 conforming to IEC 60529 IP65 |
Protective Treatment | TC |
Mechanical Robustness | Vibrations 10...150 Hz (1 gn) conforming to IEC 60068-2-6 Shocks 11 ms (30 Gn) conforming to IEC 60068-2-27 |
Ambient Air Temperature for Operation | -20…50 °C |
Fire Resistance | 960 °C conforming to IEC 60695-2-1 |
Compatibility Code | Main switch disconnector |