Schneider TeSys GV2 & GV3 - auxiliary contact GVAD1010
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NO fault signaling contact + 1NO instantaneous auxiliary contact. Instantaneous [...]
Model :GVAD1010
SKU :
This item cannot be returned or exchanged
Cash on Delivery available
- Condition: New
Description for Schneider TeSys GV2 & GV3 - auxiliary contact GVAD1010
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NO fault signaling contact + 1NO instantaneous auxiliary contact. Instantaneous auxiliary contact rated for operation up to 6A/690V AC and 6A/240V DC. Fault signaling contact rated for operation up to 2A/240V AC and 1A/60V DC. To be installed on left-hand side of the circuit breaker (1 block mounting maximum), connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Specifications
Range | TeSys TeSys Deca |
---|---|
device short name | GVAD |
product or component type | Auxiliary contact block |
Product compatibility | GV2L GV2P GV2RT GV3L GV2LE GV3P GV2ME |
Mounting location | Left side |
Auxiliary contacts operation | Fault signal 1 NO |
Pole contact composition | 2 NO |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-1 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 |
---|---|
[Ue] rated operational voltage | 48...690 V AC 24...240 V DC |
[Ith] conventional free air thermal current | 6 A 2.5 A for fault signalling |
Mechanical durability | 100000 cycles |
Minimum switching current | 5 mA |
Minimum switching voltage | 17 V |
Protection type | GB2CB... circuit breaker GG fuse 10 A |
Rated operational power in VA | 300 VA at 48 V AC-15 - electrical durability: 100000 cycles 414 VA at 690 V AC-15 - electrical durability: 100000 cycles 500 VA at 110…127 V AC-15 - electrical durability: 100000 cycles 500 VA at 500 V AC-15 - electrical durability: 100000 cycles 650 VA at 440 V AC-15 - electrical durability: 100000 cycles 720 VA at 230…240 V AC-15 - electrical durability: 100000 cycles 850 VA at 380…415 V AC-15 - electrical durability: 100000 cycles 36 VA at 24 V AC-14 - electrical durability: 1000 cycles 48 VA at 48 V AC-14 - electrical durability: 1000 cycles 72 VA at 110…127 V AC-14 - electrical durability: 1000 cycles |
Rated operational power in W | 120 W at 240 V DC-13 - electrical durability: 100000 cycles 140 W at 110 V DC-13 - electrical durability: 100000 cycles 140 W at 24 V DC-13 - electrical durability: 100000 cycles 180 W at 60 V DC-13 - electrical durability: 100000 cycles 240 W at 48 V DC-13 - electrical durability: 100000 cycles 15 W at 48 V DC-13 - electrical durability: 1000 cycles 24 W at 24 V DC-13 - electrical durability: 1000 cycles 9 W at 60 V DC-13 - electrical durability: 1000 cycles |
Tightening torque | 1.4 N.m - on screw clamp terminals |
Height | 89 mm |
Width | 9.3 mm |
Depth | 66 mm |
Net weight | 0.055 kg |
Colour | Dark grey |
environmental characteristic | Normal environment |
---|---|
Product certifications | UKCA |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 1.500 cm |
Package 1 Width | 6.500 cm |
Package 1 Length | 8.700 cm |
Package 1 Weight | 42.000 g |
Unit Type of Package 2 | BB1 |
Number of Units in Package 2 | 10 |
Package 2 Height | 9.500 cm |
Package 2 Width | 10.000 cm |
Package 2 Length | 15.000 cm |
Package 2 Weight | 469.000 g |
Unit Type of Package 3 | S02 |
Number of Units in Package 3 | 60 |
Package 3 Height | 15.000 cm |
Package 3 Width | 30.000 cm |
Package 3 Length | 40.000 cm |
Package 3 Weight | 3.104 kg |