+971 52 2525774   |   [email protected] Cash on Delivery   |   Express Delivery | Free Returns | Our Location
 REXTON Musical Instruments
Call Support

+971 52 2525774

Recently viewed items

Schneider TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 225 A - coil 220 V AC LC1F225M7

TeSys F contactor, 3 poles (3NO), 225A/690V AC-3, for motor applications up to 110kW@400V. It provides a low sealed consumption 220[...]
Model :LC1F225M7
SKU :
Assured

No Return This item cannot be returned or exchanged
Cash on Delivery Cash on Delivery available
AED 1,250.00
Rate inclusive of VAT
Sold By : MEPKart
Fulfilled by Thomsun Industries

100%
- +
Bulk Order

  •  Condition: New

Description for Schneider TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 225 A - coil 220 V AC LC1F225M7


TeSys F contactor, 3 poles (3NO), 225A/690V AC-3, for motor applications up to 110kW@400V. It provides a low sealed consumption 220V 40-400Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).

Specifications


Main
RangeTeSys
Range of productTeSys F
Product or component typeContactor
Device short nameLC1F
contactor applicationMotor control
Resistive load
utilisation categoryAC-1
AC-4
AC-3
Poles description3P
[Ue] rated operational voltage<= 460 V DC
<= 690 V AC 50/60 Hz
[Uc] control circuit voltage220 V AC 40...400 Hz
[Ie] rated operational current315 A (at <40 °C) at <= 440 V AC-1
225 A (at <55 °C) at <= 440 V AC-3
Complementary
[Uimp] rated impulse withstand voltage8 kV
[Ith] conventional free air thermal current315 A (at 40 °C)
Rated breaking capacity1800 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current1800 A 40 °C - 10 s
1000 A 40 °C - 30 s
850 A 40 °C - 1 min
560 A 40 °C - 3 min
440 A 40 °C - 10 min
Associated fuse rating315 A gG at <= 440 V
250 A aM at <= 440 V
Average impedance0.32 mOhm - Ith 315 A 50 Hz
[Ui] rated insulation voltage1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
Power dissipation per pole32 W AC-1
16 W AC-3
Overvoltage categoryIII
power pole contact composition3 NO
Motor power kW110 kW at 380...400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
129 kW at 500 V AC 50/60 Hz (AC-3)
129 kW at 660...690 V AC 50/60 Hz (AC-3)
63 kW at 220...230 V AC 50/60 Hz (AC-3)
40 kW at 400 V AC 50/60 Hz (AC-4)
Control circuit voltage limitsOperational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C)
Mechanical durability10 Mcycles
Inrush power in VA1070 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in VA9.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
Maximum operating rate2400 cyc/h 55 °C
Operating time35 ms closing (at Uc)
130 ms opening (at Uc)
Connections - terminalsControl circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: bar 2 cable(s) - busbar cross section: 32 x 4 mm
Power circuit: lugs-ring terminals 1 cable(s) 185 mm²
Power circuit: connector 1 cable(s) 185 mm²
Power circuit: bolted connection
Tightening torqueControl circuit: 1.2 N.m
Power circuit: 35 N.m
Mounting supportPlate
Heat dissipation8…9.8 W
motor power range55…100 kW at 200…240 V 3 phases
110…220 kW at 480…500 V 3 phases
110…220 kW at 380…440 V 3 phases
Motor starter typeDirect on-line contactor
Contactor coil voltage220 V AC standard
StandardsIEC 60947-1
JIS C8201-4-1
EN 60947-1
IEC 60947-4-1
EN 60947-4-1
product certificationsRINA
BV
CSA
UL
LROS (Lloyds register of shipping)
DNV
RMRoS
ABS
CB
UKCA
Compatibility codeLC1F
Control circuit typeAC at 40...400 Hz
Environment
IP degree of protectionIP20 front face with shrouds conforming to IEC 60529
IP20 front face with shrouds conforming to VDE 0106
Protective treatmentTH
Ambient air temperature for operation-5…55 °C
Ambient air temperature for storage-60…80 °C
Permissible ambient air temperature around the device-40…70 °C
Height197 mm
Width168.5 mm
Depth181 mm
Operating altitude3000 m without derating
Net weight4.75 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height21.34 cm
Package 1 Width22.1 cm
Package 1 Length23.37 cm
Package 1 Weight5.27 kg
Unit Type of Package 2P06
Number of Units in Package 212
Package 2 Height77 cm
Package 2 Width80 cm
Package 2 Length60 cm
Package 2 Weight71.236 kg
Contractual warranty
Warranty18 months

Features


Download ocuments

Customer Reviews


Write a review


Please login or register to review