Schneider Star-Delta Timing Relay - 0.05s…300s - 24V DC / 24…240V AC - 1C/O RE22R1QCMU

"This Harmony RE22 modular single function timer can be set between 1 seconds and 300 hours." "This modular single function timing relay is [...]
Model :RE22R1QCMU
SKU :
Assured

No Return This item cannot be returned or exchanged
Cash on Delivery Cash on Delivery available
AED 98.00
Rate inclusive of VAT
Sold By : MEPKart
Fulfilled by Thomsun Industries

100%
- +
Bulk Order

  •  Condition: New

Description for Schneider Star-Delta Timing Relay - 0.05s…300s - 24V DC / 24…240V AC - 1C/O RE22R1QCMU


"This Harmony RE22 modular single function timer can be set between 1 seconds and 300 hours." "This modular single function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers." "It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device." "Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC." 0 0 0 0 0 0 0 0 0 0 0 0

Specifications


Main
Range of productHarmony Timer Relays
product or component typeSingle function relay
discrete output typeRelay
device short nameRE22
Nominal output current8 A
Complementary
Contacts type and composition1 C/O timed contact, cadmium free
Time delay typeStar-delta
Time delay range10...100 s
3...30 s
0.1...1 s
0.3...3 s
0.05...0.5 s
1...10 s
30...300 s
Control typeRotary knob
Diagnostic button
[Us] rated supply voltage24 V DC
24...240 V AC 50/60 Hz
Release input voltage<= 2.4 V
Voltage range0.85...1.1 Us
Supply frequency50...60 Hz +/- 5 %
Connections - terminalsScrew terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque0.6…1 N.m conforming to IEC 60947-1
Housing materialSelf-extinguishing
Repeat accuracy+/- 0.5 % conforming to IEC 61812-1
Temperature drift+/- 0.05 %/°C
Voltage drift+/- 0.2 %/V
Setting accuracy of time delay+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Insulation resistance100 MOhm at 500 V DC conforming to IEC 60664-1
Recovery time120 ms on de-energisation
Immunity to microbreaks10 ms
Power consumption in VA35 VA at 240 V AC
Power consumption in W0.6 W at 24 V DC
Switching capacity in VA2000 VA
Minimum switching current10 mA at 5 V DC
Maximum switching current8 A
Maximum switching voltage250 V AC
Electrical durability100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-1
Mechanical durability10000000 cycles
Rated impulse withstand voltage5 kV for 1.2…50 µs conforming to IEC 60664-1
Power on delay100 ms
Creepage distance4 kV/3 conforming to IEC 60664-1
Overvoltage categoryIII conforming to IEC 60664-1
Safety reliability dataMTTFd = 285.3 years
B10d = 270000
Mounting positionAny position
Mounting support35 mm DIN rail conforming to EN/IEC 60715
Status LEDLED backlight green (steady) for dial pointer indication
LED yellow (steady) for output relay energised
LED yellow (fast flashing) for timing in progress and output relay de-energised
LED yellow (slow flashing) for timing in progress and output relay energised
width22.5 mm
net weight0.08 kg
Environment
Dielectric strength2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1
StandardsUL 508
IEC 61812-1
Directives2004/108/EC - electromagnetic compatibility
2006/95/EC - low voltage directive
Product certificationsGL
CE
CCC
EAC
UL
CSA
RCM
Ambient air temperature for operation-20…60 °C
Ambient air temperature for storage-40…70 °C
IP degree of protectionIP40 housing: conforming to IEC 60529
IP50 front face: conforming to IEC 60529
IP20 terminals: conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Vibration resistance20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn not operating for 11 ms conforming to IEC 60068-2-27
5 gn in operation for 11 ms conforming to IEC 60068-2-27
Relative humidity95 % at 25…55 °C
Electromagnetic compatibilityFast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3
Conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6
Fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height2.5 cm
Package 1 Width8.4 cm
Package 1 Length9.5 cm
Package 1 Weight90.0 g
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Height15.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight4.14 kg
Unit Type of Package 3P06
Number of Units in Package 3640
Package 3 Height80.0 cm
Package 3 Width80.0 cm
Package 3 Length60.0 cm
Package 3 Weight73.38 kg