Schneider standard auxiliary contact, circuit breaker status OF/SD/SDE/SDV, 1 changeover contact type, screwless spring terminals 29450
It is a single standard auxiliary contact that provides all the different indications remotely for ComPact NSX, ComPact NS, PowerPact Multistandard [...]
Model :29450
SKU :
This item cannot be returned or exchanged
Cash on Delivery available
- Condition: New
Description for Schneider standard auxiliary contact, circuit breaker status OF/SD/SDE/SDV, 1 changeover contact type, screwless spring terminals 29450
It is a single standard auxiliary contact that provides all the different indications remotely for ComPact NSX, ComPact NS, PowerPact Multistandard and EasyPact CVS circuit breakers. Remote status information are ON/OFF (OF), trip indication (SD) and fault-trip indication (SDE) for all circuit breakers types. The remote status information for trip indication due to an earth fault (SDV) is used for ComPact NSX and PowerPact Multistandard. The contacts are installed in the device in dedicated slots. This auxiliary contact is a common point changeover type contact with 1 normally open contact and 1 normally closed contact. The rated current is 6A and the minimum load is 100mA at 24 VDC for utilization categories are AC12/AC15/DC12/DC14. Screwless connections with spring terminals provide a fast and reliable connection. The section of connected cables is between 0.5 mm² (AWG20) and 1.5 mm² (AWG16). It complies with IEC 60947-5-1 standard.
Specifications
Product or component type | Auxiliary contact |
---|---|
device short name | OF SD SDE SDV |
Device application | Breaker status monitoring |
Range compatibility | ComPact (ComPact NS630b...1600) ComPact (ComPact NS1600b...3200) ComPact (ComPacT INS) ComPact (Compact INV) ComPact (ComPact NSX) EasyPact (EasyPact CVS) PowerPact (PowerPact Multistandard) ComPact (ComPact NSX DC) |
Signal contacts composition | 1 NO/NC |
Fault type | General electric fault |
---|---|
Local signalling | ON/OFF indication for open/close Trip indicator for relay trip indicator Fault trip for electrical fault |
Auxiliary contacts type | Standard |
Mounting mode | Clip-on |
[Ith] conventional free air thermal current | 5 A |
Breaking capacity (A) | AC-12: 6 A at 24 V AC 50/60 Hz AC-12: 6 A at 48 V AC 50/60 Hz AC-12: 6 A at 110 V AC 50/60 Hz AC-12: 6 A at 220/240 V AC 50/60 Hz AC-12: 6 A at 380/440 V AC 50/60 Hz AC-12: 6 A at 480 V AC 50/60 Hz AC-12: 6 A at 660/690 V AC 50/60 Hz AC-15: 6 A at 24 V AC 50/60 Hz AC-15: 6 A at 48 V AC 50/60 Hz AC-15: 5 A at 110 V AC 50/60 Hz AC-15: 4 A at 220/240 V AC 50/60 Hz AC-15: 2 A at 380/440 V AC 50/60 Hz AC-15: 1.5 A at 480 V AC 50/60 Hz AC-15: 0.1 A at 660/690 V AC 50/60 Hz DC-12: 6 A at 24 V DC 50/60 Hz DC-12: 2.5 A at 48 V DC 50/60 Hz DC-12: 0.6 A at 110 V DC 50/60 Hz DC-12: 0.3 A at 250 V DC 50/60 Hz DC-14: 1 A at 24 V DC 50/60 Hz DC-14: 0.2 A at 48 V DC DC-14: 0.05 A at 110 V DC DC-14: 0.03 A at 250 V DC |
Minimum load | 100 mA at 24 V DC |
Auxiliary connection terminal | Spring 0.5…1.5 mm² (AWG 20...AWG 16) |
Accessory / separate part category | Spare part for Compact NS630b...1600 Spare part for Compact NS1600b...3200 |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 1.400 cm |
Package 1 Width | 7.000 cm |
Package 1 Length | 7.000 cm |
Package 1 Weight | 16.900 g |
Unit Type of Package 2 | BB1 |
Number of Units in Package 2 | 10 |
Package 2 Height | 4.500 cm |
Package 2 Width | 16.000 cm |
Package 2 Length | 16.000 cm |
Package 2 Weight | 177.000 g |
Unit Type of Package 3 | S03 |
Number of Units in Package 3 | 300 |
Package 3 Height | 30.000 cm |
Package 3 Width | 30.000 cm |
Package 3 Length | 40.000 cm |
Package 3 Weight | 5.785 kg |
Warranty | 18 months |
---|