Recently viewed items
Schneider residual current circuit breaker - 4 poles - 40 A - class AC 300 mA 11030
This product is a Domae residual current circuit breaker (RCCB). It is a 4P circuit breaker with 40A In rated current, [...]
Model :11030
SKU :
This item cannot be returned or exchanged
Cash on Delivery available
only 1 item(s) remaining
AED 94.50
Rate inclusive of VAT
Sold By : MEPKart
Fulfilled by Thomsun Industries
- Condition: New
Description for Schneider residual current circuit breaker - 4 poles - 40 A - class AC 300 mA 11030
This product is a Domae residual current circuit breaker (RCCB). It is a 4P circuit breaker with 40A In rated current, a sensitivity of 300mA with a AC type protection class. This product protects against electrical shock by indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. It has control of on load electric circuit, already protected against overloads and short circuit. This product is compliant with IEC 61008-1 standard. The Ue operational voltage is 400VAC. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The dimensions are (W) 72mm x (H) 81mm x (D) 76mm. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -5°C to 40°C. The storage temperature is from -40°C to 60°C.
Specifications
Range | Domae |
---|---|
Product or component type | Residual current circuit breaker (RCCB) |
device short name | RCCB |
Poles description | 4P |
Earth-leakage protection class | Type AC |
Neutral position | Left |
---|---|
Device location in system | Outgoer |
[In] rated current | 40 A |
Network type | AC |
Network frequency | 50/60 Hz |
[Ue] rated operational voltage | 400 V AC 50/60 Hz conforming to IEC 61008 |
Residual current tripping technology | Electromechanical |
Earth-leakage sensitivity | 300 mA |
Earth-leakage protection time delay | Instantaneous |
Rated conditional short-circuit current | 6 kA 40 A |
[Ui] rated insulation voltage | 440 V |
[Uimp] rated impulse withstand voltage | 4 kV |
Control type | Toggle |
Mounting mode | Fixed |
Mounting support | 35 mm symmetrical DIN rail |
Connection pitch | 18 mm between phase and neutral |
9 mm pitches | 8 |
Height | 81 mm |
Width | 72 mm |
Depth | 76 mm |
Connections - terminals | Tunnel type terminals (downstream) 25 mm² flexible Tunnel type terminals (downstream) 35 mm² rigid Tunnel type terminals (upstream) 25 mm² flexible Tunnel type terminals (upstream) 35 mm² rigid |
standards | IEC 61008 |
---|---|
Pollution degree | 2 |
Tropicalisation | 2 conforming to IEC 61008 |
Operating altitude | 2000 m |
Ambient air temperature for operation | -5…40 °C |
Ambient air temperature for storage | -40…60 °C |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 7.500 cm |
Package 1 Width | 8.400 cm |
Package 1 Length | 9.000 cm |
Package 1 Weight | 347.900 g |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 27 |
Package 2 Height | 30.000 cm |
Package 2 Width | 30.000 cm |
Package 2 Length | 40.000 cm |
Package 2 Weight | 9.940 kg |
Warranty | 18 months |
---|