Description for Schneider residual current circuit breaker - 2 poles - 63 A - class AC 100 mA 16819
This is a Domae residual current circuit breaker (RCCB). It is a 2P circuit breaker with In rated current of 63A, AC type protection class and a 100mA earth leakage sensitivity. This product protects against electrical shock by indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. It has control of on load electric circuit, already protected against overloads and short circuit. This product is compliant with IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 500A. The (Inc/IΔc) conditional rated short circuit current is 3000A. The electrical endurance is up to 2000 cycles. The mechanical endurance is up to 5000 cycles. The Ue operational voltage is 230VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The dimensions are (W) 36mm x (H) 81mm x (D) 76mm. The weight is 0.18kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -5°C to 40°C. The storage temperature is from -40°C to 60°C.
Specifications
Range | Domae |
---|---|
Product or component type | Residual current circuit breaker (RCCB) |
device short name | RCCB |
Poles description | 2P |
Earth-leakage protection class | Type AC |
Neutral position | Left |
---|---|
Device location in system | Outgoer |
[In] rated current | 63 A |
Network type | AC |
Network frequency | 50 Hz |
[Ue] rated operational voltage | 230 V AC 50 Hz conforming to IEC 61008-1 |
Residual current tripping technology | Electromechanical |
Earth-leakage sensitivity | 100 mA |
Earth-leakage protection time delay | Instantaneous |
Rated breaking and making capacity | Im = 500 A 230 V conforming to IEC 61008-1 |
Rated conditional short-circuit current | Inc 3000 A 63 A |
[Ui] rated insulation voltage | 440 V AC 50 Hz conforming to IEC 61008-1 |
[Uimp] rated impulse withstand voltage | 4 kV conforming to IEC 61008-1 |
Contact position indicator | Yes |
Control type | Toggle |
Mounting mode | Fixed |
Mounting support | 35 mm symmetrical DIN rail |
Comb busbar and distribution block compatibility | YES |
Connection pitch | 18 mm between phase and neutral |
9 mm pitches | 4 |
Height | 81 mm |
Width | 36 mm |
Depth | 76 mm |
Product weight | 0.18 kg |
Mechanical durability | 5000 cycles |
Electrical durability | 2000 cycles 230 V AC 50 Hz conforming to IEC 61008-1 |
Connections - terminals | Tunnel type terminals (downstream) 1…25 mm² flexible Tunnel type terminals (downstream) 1…35 mm² rigid Tunnel type terminals (upstream) 1…25 mm² flexible Tunnel type terminals (upstream) 1…35 mm² rigid |
standards | IEC 60529 IEC 60068-1 IEC 61008-1 |
---|---|
Product certifications | VDE |
IP degree of protection | IP20 conforming to IEC 60529 |
Tropicalisation | 2 conforming to IEC 61008 |
Operating altitude | 2000 m |
Ambient air temperature for operation | -5…40 °C |
Ambient air temperature for storage | -40…60 °C |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 4.0 cm |
Package 1 Width | 8.5 cm |
Package 1 Length | 9.0 cm |
Package 1 Weight | 210 g |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 54 |
Package 2 Height | 30.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 11.781 kg |
Unit Type of Package 3 | P12 |
Number of Units in Package 3 | 432 |
Package 3 Height | 44.4 cm |
Package 3 Width | 80 cm |
Package 3 Length | 120 cm |
Package 3 Weight | 106.248 kg |