Recently viewed items
Schneider residual current circuit breaker - 2 poles - 40 A - class AC 30 mA 11025
This is a Domae residual current circuit breaker (RCCB). It is a 2P circuit breaker with In rated current of 40A, [...]
Model :11025
SKU :
This item cannot be returned or exchanged
Cash on Delivery available
- Condition: New
Description for Schneider residual current circuit breaker - 2 poles - 40 A - class AC 30 mA 11025
This is a Domae residual current circuit breaker (RCCB). It is a 2P circuit breaker with In rated current of 40A, AC type protection class and a 30mA earth leakage sensitivity. This product protects against electrical shock by direct or indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. It has control of on load electric circuit, already protected against overloads and short circuit. This product is compliant with IEC 61008-1 standard. The Ue operational voltage is 230VAC. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The dimensions are (W) 36mm x (H) 81mm x (D) 76mm. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -5°C to 40°C. The storage temperature is from -40°C to 60°C.
Specifications
Range | Domae |
---|---|
Product or component type | Residual current circuit breaker (RCCB) |
device short name | RCCB |
Poles description | 2P |
Earth-leakage protection class | Type AC |
Neutral position | Left |
---|---|
Device location in system | Outgoer |
[In] rated current | 40 A |
Network type | AC |
Network frequency | 50/60 Hz |
[Ue] rated operational voltage | 230 V AC 50/60 Hz conforming to IEC 61008 |
Residual current tripping technology | Electromechanical |
Earth-leakage sensitivity | 30 mA |
Earth-leakage protection time delay | Instantaneous |
Rated conditional short-circuit current | 6 kA 40 A |
[Ui] rated insulation voltage | 440 V |
[Uimp] rated impulse withstand voltage | 4 kV |
Control type | Toggle |
Mounting mode | Fixed |
Mounting support | 35 mm symmetrical DIN rail |
Connection pitch | 18 mm between phase and neutral |
9 mm pitches | 4 |
Height | 81 mm |
Width | 36 mm |
Depth | 76 mm |
Connections - terminals | Tunnel type terminals (downstream) 25 mm² flexible Tunnel type terminals (downstream) 35 mm² rigid Tunnel type terminals (upstream) 25 mm² flexible Tunnel type terminals (upstream) 35 mm² rigid |
standards | IEC 61008 |
---|---|
Pollution degree | 2 |
Tropicalisation | 2 conforming to IEC 61008 |
Operating altitude | 2000 m |
Ambient air temperature for operation | -5…40 °C |
Ambient air temperature for storage | -40…60 °C |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 4.000 cm |
Package 1 Width | 8.500 cm |
Package 1 Length | 9.000 cm |
Package 1 Weight | 207.000 g |
Unit Type of Package 2 | BB1 |
Number of Units in Package 2 | 6 |
Package 2 Height | 9.500 cm |
Package 2 Width | 10.000 cm |
Package 2 Length | 26.000 cm |
Package 2 Weight | 1.267 kg |
Unit Type of Package 3 | S03 |
Number of Units in Package 3 | 54 |
Package 3 Height | 30.000 cm |
Package 3 Width | 30.000 cm |
Package 3 Length | 40.000 cm |
Package 3 Weight | 11.958 kg |