Recently viewed items
Schneider phase control relay RM17-T - range 183..528 V AC RM17TG00
This Harmony RM17-TG relay allows monitoring of power supply circuits in 3-phase networks. This modular multi function 3-phase supply control [...]
Model :RM17TG00
SKU :
This item cannot be returned or exchanged
Cash on Delivery available
- Condition: New
Description for Schneider phase control relay RM17-T - range 183..528 V AC RM17TG00
This Harmony RM17-TG relay allows monitoring of power supply circuits in 3-phase networks. This modular multi function 3-phase supply control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slimmest form-factors with 17.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with screw trimmers. The product monitors its own power supply, when the power supply is abnormal, the output relay de-energizes. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
Specifications
Range of product | Harmony Control Relays |
---|---|
Product or component type | 3-phase control relay |
Relay type | Control relay |
Product specific application | For 3-phase supply |
Relay name | RM17TG |
Relay monitored parameters | Phase sequence Phase failure detection (2 or more phase cut) |
time delay | Without |
Switching capacity in VA | 1250 VA |
Measurement range | 208...480 V voltage AC |
Contacts type and composition | 1 C/O |
[Uc] control circuit voltage | 208...480 V |
Maximum switching voltage | 250 V AC 250 V DC |
---|---|
Minimum switching current | 10 mA at 5 V DC |
Supply voltage limits | 183…528 V AC |
Control circuit voltage limits | - 12 % + 10 % Un |
Power consumption in VA | 0…22 VA at 400 V AC 50 Hz |
Voltage detection threshold | < 100 V AC |
Control circuit frequency | 50...60 Hz +/- 10 % |
Output contacts | 1 C/O |
Nominal output current | 5 A |
Measurement voltage limits | 183…528 V AC |
delay at power up | 650 ms |
Voltage range | 183...528 V |
Response time | <= 130 ms (in the event of a fault) |
marking | CE |
Overvoltage category | III conforming to IEC 60664-1 |
Insulation resistance | > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 |
[Ui] rated insulation voltage | 400 V conforming to IEC 60664-1 |
Supply frequency | 50/60 Hz +/- 10 % |
Operating position | Any position without derating |
Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end |
Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
Housing material | Self-extinguishing plastic |
Local signalling | LED (yellow) for relay ON |
Mounting support | 35 mm symmetrical DIN rail conforming to EN/IEC 60715 |
Electrical durability | 100000 cycles |
Mechanical durability | 30000000 cycles |
Operating rate | <= 360 operations/hour full load |
Utilisation category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 |
Safety reliability data | MTTFd = 924.6 years B10d = 850000 |
Width | 17.5 mm |
Product weight | 0.13 kg |
Electromagnetic compatibility | Emission standard for industrial environments conforming to EN/IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 Immunity for industrial environments conforming to EN/IEC 61000-6-2 |
---|---|
standards | EN/IEC 60255-1 |
Product certifications | C-Tick GL CSA UL GOST |
Directives | 73/23/EEC - low voltage directive 89/336/EEC - electromagnetic compatibility |
Ambient air temperature for storage | -40…70 °C |
Ambient air temperature for operation | -20…50 °C |
Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1 |
Shock resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
Pollution degree | 3 conforming to IEC 60664-1 |
Dielectric test voltage | 2 kV, 1 min AC 50 Hz |
Non-dissipating shock wave | 4 kV |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 2.700 cm |
Package 1 Width | 7.800 cm |
Package 1 Length | 9.500 cm |
Package 1 Weight | 89.000 g |
Unit Type of Package 2 | S02 |
Number of Units in Package 2 | 48 |
Package 2 Height | 15.000 cm |
Package 2 Width | 30.000 cm |
Package 2 Length | 40.000 cm |
Package 2 Weight | 4.715 kg |
Unit Type of Package 3 | P06 |
Number of Units in Package 3 | 768 |
Package 3 Height | 75.000 cm |
Package 3 Width | 60.000 cm |
Package 3 Length | 80.000 cm |
Package 3 Weight | 81.828 kg |
Warranty | 18 months |
---|