The Hager X160 H3 Moulded Case Circuit Breaker (MCCB) 80A is engineered for robust electrical protection in industrial and commercial applications. Featuring a 25kA short-circuit breaking capacity, this 3-pole breaker is designed to safeguard electrical circuits against overloads and short circuits. The thermal-magnetic trip unit (TM F/F) provides reliable protection, while the compact design allows for easy installation on a DIN rail. With compliance to IEC 60947-2 standards, the Hager X160 80A MCCB offers both safety and durability, making it an ideal choice for high-performance electrical systems.
Key Features:
- Rated Current: 80A, with adjustable thermal protection based on temperature variations.
- High Breaking Capacity:
- 35kA at 230V AC and 240V AC
- 25kA at 400V AC and 415V AC
- 25kA at 380V AC
- Thermal-Magnetic Trip Unit: Ensures precise overload and short-circuit protection.
- Compact Dimensions: 75mm width and 130mm height, suitable for space-saving installations.
- Endurance: Rated for 1000 electrical cycles and 4000 mechanical operations, ensuring long-lasting performance.
- Thermal Adjustment Range: 80A, adjustable based on environmental temperature conditions.
- Screw-Type Connection: Compatible with flexible and rigid cables, connection range of 4 to 70mm².
- Motor Drive Option: Available for enhanced control functionalities.
- IEC 60947-2 Compliant: Meets international standards for electrical protection, ensuring safe and reliable operations.
- Operating Temperature Range: -25°C to +60°C, ensuring reliability in diverse environmental conditions.
- Altitude Resistance: Rated for operation up to 2000 meters above sea level.
- Power Loss: Total power loss of 18.9W at rated current, with 6.3W per pole.
Specifications:
- Rated Operational Voltage: 220V / 415V AC
- Rated Insulation Voltage: 690V
- Rated Impulse Withstand Voltage: 8kV
- Rated Ultimate Short-Circuit Breaking Capacity:
- 35kA at 230V AC and 240V AC
- 25kA at 400V AC and 415V AC
- 25kA at 380V AC
- Endurance: 1000 electrical cycles, 4000 mechanical operations
- Temperature Range: -25°C to +60°C for reliable operation in varying environments
- Connection Type: Screw-type, compatible with flexible and rigid cables
- Standards Compliant: IEC 60947-2, ensuring safe and reliable electrical protection
- Environmental Protection: Degree of pollution 3 as per IEC 60664/60947-2
The Hager X160 H3 80A MCCB is designed for industrial environments, ensuring protection against short circuits and overloads. Its high breaking capacity and long lifespan make it ideal for critical electrical systems.