Hager Moulded Case Circuit Breaker H3 X160 TM FIX 3P3D 63A 25kA CTC - HHA063Z
- Condition: New
Description for Hager Moulded Case Circuit Breaker H3 X160 TM FIX 3P3D 63A 25kA CTC - HHA063Z
The Hager X160 H3 Moulded Case Circuit Breaker (MCCB) 63A is designed to protect electrical circuits against overloads and short circuits. With a 25kA short-circuit breaking capacity, it offers reliable protection for 3-phase systems. The breaker is equipped with a thermal-magnetic trip unit (TM F/F), ensuring accurate overload and short-circuit protection. This compact device is ideal for commercial and industrial applications, designed for easy DIN rail mounting. Compliant with IEC 60947-2 standards, the Hager X160 63A MCCB guarantees safety and efficiency in electrical protection.
Key Features:
- Rated Current: 63A, with adjustable thermal protection settings according to temperature variations.
- High Breaking Capacity:
- 35kA at 230V AC and 240V AC
- 25kA at 400V AC and 415V AC
- 25kA at 380V AC
- Thermal-Magnetic Trip Unit: Provides accurate protection against overloads and short circuits.
- Compact Design: 3P3D type, 3-pole, designed for 3-phase systems, with dimensions of 75mm width and 130mm height for space-saving installation.
- Endurance: Rated for 1000 electrical cycles and 4000 mechanical operations, ensuring a long lifespan.
- Thermal Adjustment Range: 63A, adjustable based on operational temperature conditions.
- Screw-Type Connection: Compatible with flexible and rigid cables, with a connection range of 4 to 70mm².
- Motor Drive Option: Available for additional control capabilities.
- IEC 60947-2 Compliant: Conforms to international standards for electrical protection, ensuring safe and reliable installations.
- Operating Temperature Range: -25°C to +60°C for reliable performance in varying environments.
- Altitude Resistance: Rated for use up to 2000 meters.
- Power Loss: Total power loss of 21.3W under rated current, with 7.1W power loss per pole at In.
Specifications:
- Rated Operational Voltage: 220V / 415V AC
- Rated Insulation Voltage: 690V
- Rated Impulse Withstand Voltage: 8kV
- Rated Ultimate Short-Circuit Breaking Capacity:
- 35kA at 230V AC and 240V AC
- 25kA at 400V AC and 415V AC
- 25kA at 380V AC
- Endurance: 1000 electrical cycles, 4000 mechanical operations
- Temperature Range: Operates from -25°C to +60°C
- Connection Type: Screw-type, suitable for flexible and rigid cables
- Standards Compliant: IEC 60947-2 for reliable electrical protection
- Environmental Protection: Degree of pollution 3 as per IEC 60664/60947-2
The Hager X160 H3 63A MCCB is engineered for reliable, long-lasting protection in both commercial and industrial applications. Its high breaking capacity and adjustable thermal settings make it an excellent choice for demanding electrical environments.