Hager Moulded Case Circuit Breaker H3 X160 TM FIX 3P3D 32A 25kA CTC - HHA032Z
Model :HHA032Z
SKU :
7 days retun policy available
Cash on Delivery available
- Condition: New
Description for Hager Moulded Case Circuit Breaker H3 X160 TM FIX 3P3D 32A 25kA CTC - HHA032Z
The Hager X160 H3 Moulded Case Circuit Breaker (MCCB) 32A is designed for superior electrical protection in industrial and commercial applications. With a 25kA short-circuit breaking capacity, this MCCB ensures reliable protection against overloads and short circuits. The thermal-magnetic trip unit (TM F/F) provides precise protection, while its compact design makes it easy to install. This breaker adheres to IEC 60947-2 standards, offering safe and durable electrical protection for your systems.
Key Features:
- Rated Current: 32A, with adjustable thermal protection for varying temperatures.
- High Breaking Capacity:
- 35kA at 230V AC and 240V AC
- 25kA at 400V AC and 415V AC
- 25kA at 380V AC
- Thermal-Magnetic Trip Unit: Ensures both overload and short-circuit protection with accurate tripping.
- Compact Design: 3P3D type, 3-pole, designed for 3-phase systems with dimensions of 75mm width and 130mm height, easy to install on DIN rails.
- Endurance: 1000 electrical cycles and 4000 mechanical operations, ensuring long-lasting performance.
- Thermal Adjustment Range: 32A, adjustable based on operational temperature.
- Screw-Type Connection: For flexible (4 to 70mm²) and rigid (4 to 95mm²) cables.
- Motor Drive Optional: Offers flexibility for additional control.
- Compliant with IEC 60947-2 Standards: Ensures reliability and safety in electrical installations.
- Temperature Range: Operates efficiently from -25°C to +60°C.
- Altitude Resistance: Rated for altitudes up to 2000 meters.
- Power Loss: Total power loss of 8.4W under rated current, with 2.8W power loss per pole at In.
Specifications:
- Rated Operational Voltage: 220V / 415V AC
- Rated Insulation Voltage: 690V
- Rated Impulse Withstand Voltage: 8kV
- Rated Ultimate Short-Circuit Breaking Capacity:
- 35kA at 230V AC and 240V AC
- 25kA at 400V AC and 415V AC
- 25kA at 380V AC
- Endurance: 1000 electrical cycles, 4000 mechanical operations
- Temperature Range: Operates from -25°C to +60°C
- Connection Type: Screw-type, suitable for flexible and rigid cables
- Standards Compliant: IEC 60947-2 for safe electrical installations
- Environmental Protection: Degree of pollution 3 as per IEC 60664/60947-2
The Hager X160 H3 32A MCCB offers excellent protection for electrical systems, ensuring high performance, safety, and compliance with international standards.