Description for Hager Moulded Case Circuit Breaker H3 X160 TM FIX 3P3D 16A 25kA CTC - HHA016Z
The Hager X160 H3 Moulded Case Circuit Breaker (MCCB) 16A is a high-performance protection device designed for 3-phase, 3-pole systems. With a 25kA breaking capacity at 415V AC, it ensures reliable protection against overloads and short circuits. The breaker features a thermal-magnetic trip unit (TM F/F) for effective overload and short-circuit protection. This MCCB is compliant with IEC 60947-2 standards, ensuring long-lasting, safe operation for commercial and industrial electrical installations.
Key Features:
- Rated Current: 16A with adjustable thermal protection for various temperature settings.
- High Breaking Capacity: 35kA at 230V AC and 240V AC, providing superior short-circuit protection.
- Thermal-Magnetic Trip Unit: For reliable overload and short-circuit protection.
- Compact Design: 3P3D type, designed for 3-phase systems with a width of 75mm and height of 130mm for easy installation.
- Rated Ultimate Short-Circuit Breaking Capacity:
- 35kA at 230V AC and 240V AC
- 25kA at 400V AC and 415V AC
- 25kA at 380V AC
- Endurance: 1000 electrical cycles and up to 4000 mechanical operations for dependable performance.
- Thermal Adjustment Range: 16A with adjustable settings for precise protection based on operating temperature.
- Connection Type: Screw-type connection for easy and secure installation with flexible (4 to 70mm²) and rigid (4 to 95mm²) cables.
- Standards Compliant: IEC 60947-2 for high-quality protection and operational reliability.
- Temperature and Humidity Resilience: Operates efficiently in environments with temperatures ranging from -25°C to +60°C and altitudes up to 2000m.
Specifications:
- Rated Operational Voltage: 220V / 415V AC
- Rated Insulation Voltage: 690V
- Rated Impulse Withstand Voltage: 8kV
- Rated Ultimate Short-Circuit Breaking Capacity:
- 35kA at 230V AC
- 35kA at 240V AC
- 25kA at 400V AC and 415V AC
- 25kA at 380V AC
- Endurance: 1000 electrical cycles and 4000 mechanical operations
- Temperature Range: Suitable for operating conditions up to 50°C
- Connection: Screw-type connection for flexible and rigid cables
- Environmental Protection: Rated for degree of pollution 3 as per IEC 60664/60947-2
- Compliance: REACH and RoHS compliant
The Hager X160 H3 16A MCCB provides reliable protection for your electrical systems with high breaking capacity, durable performance, and simple installation.